Coal Mine Hydraulic Support Protection Mesh: Inspection in Service

A mining net inspection is not a search for damage. It is a check on whether four specific things have moved since the last walk, and most of them move slowly enough to be invisible unless there is a record to compare against.

The four are the free length at the hooks, the hanging height above the deck, the open area of the panel, and the condition of the wire at the fixings.

This article sets out what a support mesh wear check is looking for, the three rhythms at which it should happen, the four mechanisms that wear a panel out, how to record an underground net check so that it means something later, and how to decide between re-hanging, repairing and replacing.

1. What a Mining Net Inspection Is Looking For

A mining net inspection begins with a decision about what would count as a finding, because everything on a face looks worn after a month.

The useful findings are the ones that predict a failure rather than the ones that describe a condition. A wire with a bright rub mark is a condition; the same wire with two broken strands at the hook is a prediction.

So the inspection is built around four predictors: broken strands at a fixing, a free length that has drifted from the drawing, a bottom edge that has dropped towards the deck, and a panel that has stopped moving with its supports.

Each of the four has a threshold and each has an action, and a mining net inspection that produces a list of observations without either is a walk rather than a check.

2. Three Rhythms for Support Mesh Wear Checks

Support mesh wear is checked on three rhythms, and they answer different questions.

RhythmWhoQuestion answered
Every shiftFace team, walking pastIs anything hanging loose or in the walkway
WeeklyNominated person, with a lightHas the free length or height drifted
End of blockEngineer, with the recordIs the panel going to last the next block

The shift check is a glance and it is deliberately undemanding, because a check that takes time will stop being done. It looks for a panel that is hanging by one hook, a panel on the floor, and a panel in the walkway.

The weekly check is the one that does the work. It takes a light, a tape and the drawing, and it measures the free length and the hanging height at three supports rather than at all of them.

Three is enough because the drift is a trend rather than a local defect, and a panel that has moved at one support has almost always moved at its neighbours too. A weekly underground net check that samples properly finds more than a monthly one that tries to cover the whole face.

The end-of-block check is a comparison against the record, and it is the one that decides whether a specification is right for the next block rather than whether this panel is sound.

3. The Four Mechanisms That Wear a Support Mesh

Wire in a face panel is lost in four ways, and they look similar in a photograph.

The first is fatigue at the fixing, which starts as a rub mark and ends as a broken strand at the hook. It is driven by cyclic movement and it is accelerated by a short free length or a fixing that will not rotate.

The second is abrasion, from the panel rubbing the canopy side plate or the conveyor structure. It removes coating first and wire second, and it is visible as a polished band rather than a break.

The third is corrosion, which on a face is concentrated at the ferrules and at any point where coal fines sit against the wire. It reduces the section from the inside of a joint where nothing can be seen.

The fourth is overload, which shows as a permanently distorted aperture or a bagged panel that does not recover. It is not wear in the ordinary sense and it should not be treated as a maintenance item.

Separating the four is the point of the check, because each has a different remedy. Fatigue is a geometry problem, abrasion is a clearance problem, corrosion is a material problem, and overload is a specification problem, and a face that treats all four as wear will replace panels without changing any of them.

4. Underground Net Check: The Walk and What To Record

An underground net check is worth structuring, because an unstructured one produces a page of adjectives.

The walk goes with the airflow or against it, always in the same direction, so that the same panel is seen from the same side each time. Panels are identified by support number rather than by position, because position changes as the face advances.

At each of the three sampled supports, the record takes four figures: free length in millimetres, bottom edge height above the deck, the number of broken strands within a hand's width of each hook, and whether the panel is hanging square.

Photographs are taken from the walkway side at the same distance each time, with the support number in the frame. A photograph without a scale and a number is a picture, and it cannot be compared with the one taken last month.

A complete underground net check therefore produces four figures and one photograph per sampled support, on a single sheet that fits in a pocket. Length is the enemy of a check that has to be repeated every week for the life of a face.

5. Measuring Support Mesh Wear Rather Than Judging It

The measurement that matters most is the one nobody takes, which is the remaining wire diameter at the point of worst wear.

A caliper or a wire gauge held against a suspect wire will show a loss of section long before a strand breaks. On a galvanised panel the surface is rough and a single reading is unreliable, so the practice is three readings at the same point and the lowest one recorded.

The threshold is usually a ten percent loss of diameter, which corresponds to roughly a fifth of the section area. Beyond that the wire is carrying load on a reduced section and the panel should be scheduled for replacement rather than watched.

Where no gauge is available, the same judgement can be made from a comparison wire: a short offcut of the same rope kept in the store, held against the suspect wire in the same light. It is cruder and it is better than a memory.

6. After an Underground Net Check: Re-hang, Repair or Replace

Three actions are available and they are not interchangeable.

Re-hanging is the correct response to a free length or a height that has drifted, and it is a maintenance action. It restores the geometry without touching the wire, and it should be done to the figure on the drawing rather than to a figure that looks better.

A support mesh wear finding that ends in a re-hang should be logged as such, because a panel re-hung twice at the same support is telling you the bracket has opened rather than that the fitter was careless.

Repair is limited to coating damage on a panel that is otherwise sound, and it has to be done with a thinned coating at a controlled film thickness. A repair that closes an aperture has traded one problem for another.

Replacement is the response to broken strands at a fixing, a wire below the diameter threshold, a permanently distorted aperture, or a panel that has stopped moving with its supports. Repairing any of those in place disturbs the surrounding panel and the panel usually returns to the store in a worse state than it left.

7. Mining Net Inspection Records and the Trend They Show

A single inspection produces a snapshot. Twelve produce a trend, and the trend is what changes a specification.

The figure worth plotting is the free length at the sampled supports against time, because it drifts in one direction as the brackets wear and the hooks open. A free length that has grown by thirty millimetres over a block is telling you the bracket is the item to change, not the panel.

The second figure worth plotting is broken strands per panel per block. A face that starts at zero and ends at four has a fatigue problem that a thicker rope will not fix, because a thicker rope is stiffer and puts more strain into the same hook.

Hebei Longen Wire Mesh Products Co Ltd supplies each panel with its as-supplied figures on a plate, so that a reading underground can be compared with a number rather than with an impression. Hebei Longen Wire Mesh Products also keeps the free length used on each face on file, which is how a wear claim can be checked against the panel that was actually supplied.

8. Two Faces Where the Inspection Record Changed the Interval

On a face with a weekly check, the free length at the sampled supports grew from a hundred and forty to a hundred and seventy millimetres over two blocks. Nothing broke, and the record was the reason: the brackets were replaced at the end of the second block and the free length returned to the drawing figure.

On a second face there was no record and the panels were replaced when they began to break at the hooks. The replacement panels broke in the same place within a month, because the brackets had not been changed. The second set cost more than the first, and the difference between the two faces was a page of figures.

Longen Wire Mesh Products supplies a blank record sheet with each order of more than twenty panels, laid out in the same four columns as the walk. Longen does not need it returned, though a returned sheet is read and answered.

9. Frequently Asked Questions

9.1 How often should a mining net inspection be done?

Every shift for a visual glance, weekly for a measured check, and once per block for a comparison against the record. The weekly check is the one that earns its time, because the drift it detects is slow enough to be invisible day to day and fast enough to matter over a block. A face that measures monthly is usually measuring too late to catch a bracket problem before it has cost a set of panels. The interval should shorten where the record shows drift, and it can lengthen where two blocks have shown none.

9.2 What counts as a broken strand that needs action?

One broken strand at a hook is a finding and two is an action. A single strand in the middle of a panel is recorded and watched, because the panel is still catching material and the loss of section is small. The distinction matters because the consequence differs: a break at the hook is where the load arrives and it propagates, while a break in the middle is sharing load with its neighbours. Any break within a hand's width of a fixing should be treated as being at the fixing.

9.3 Can support mesh wear be repaired underground?

Coating damage can be, and wire damage cannot. A field repair to a rope is a joint, and a joint underground is made in poor light with a hand tool, which is the condition in which ferrules slip later. A panel with a broken strand at a fixing should be replaced and returned, and the returned panel is worth examining because it carries the evidence of why it failed. Repairing it on the face usually moves the failure to the next wire along rather than removing it.

9.4 Why do replacement panels fail in the same place as the originals?

Because the panel was not the cause. A break at the hook is usually a bracket that has worn, a free length that is too short, or a fixing that will not rotate, and none of those is supplied with the panel. Replacing the panel without measuring the free length and inspecting the bracket reproduces the original condition with a new rope. The check to make before any replacement order is the free length at three adjacent supports and the condition of the hook surface.

9.5 Does a humid face need a different inspection interval?

It needs a different inspection, rather than a different interval. Corrosion on a wet face advances from inside a ferrule where nothing is visible, so the check moves from the wire to the joints and the interval stays the same. The useful addition is a look at the deposit under each hook, since fines that stay wet hold water against the wire and the section loss happens there first. A dry face can go longer between checks of the same kind without any change of panel.