Fall Protection Safety Net for Atriums, Stairs and Lift Shafts

A hotel in Eastern Europe had a six storey atrium with a glass roof, a cantilevered walkway on each level, and no protection between the walkway and the floor below. The architect resisted a net for two years on the grounds that it would ruin the glazing. The version that was eventually installed was a 60 mm aperture panel in 316 rope, and from the lobby floor it reads as a slight grey haze rather than a barrier.

An atrium safety net carries a heavier design brief than a roof net, because it is seen from below by everyone who uses the building. That makes aperture, colour and geometry as important as load capacity, and it makes the installation sequence a matter of programme rather than convenience.

This article covers the three settings where a net works inside a building, the details that decide whether a lift shaft protection net can be installed at all, the void fall protection questions that come up on every stair core, and the handover checks that keep an interior installation maintainable.

1. Why an Atrium Safety Net Differs From a Roof Net

A roof net is judged by the people who maintain it. An atrium safety net is judged by everyone who walks underneath, and that changes almost every choice in the specification.

Light comes first. A net at 50 mm aperture with a 4 mm rope reduces daylight noticeably in a space that depends on a glazed roof, while the same panel at 80 mm lets most of it through.

Then comes containment. In a public atrium the falling object is often a phone, a bag or a glass rather than a tool, and an 80 mm aperture passes a phone. The design has to decide whether those items matter, and that decision belongs to the client rather than to the supplier.

The third difference is access. A roof net is reached by a ladder or a lift; an atrium net may need a mobile tower standing on a finished floor, with protection for the floor and for the public below.

One more difference is who owns the decision. An atrium safety net is usually chosen by the architect and signed off by the fire engineer, and the two rarely want the same thing. The architect wants the panel to disappear and the fire engineer wants the smoke path unchanged.

Longen sends a sample panel to site for that reason, so that the client can hold it against the glazing in daylight before the order is placed rather than after the crate arrives.

2. Lift Shaft Protection Net: Working Inside the Shaft

A lift shaft is the most awkward location on any project. It is a tall, narrow, unlit box with a pit at the bottom, and everything has to be done from a platform that is itself hanging in the void.

A lift shaft protection net is usually installed as a series of horizontal panels at each floor level, so that a fall from any landing is arrested within one storey. The alternative is a continuous vertical net fixed to the shaft wall, which is more robust and harder to install.

The horizontal arrangement suits construction sites, where lifting equipment and materials pass through the shaft. A panel that can be lifted out and refitted around a temporary platform keeps the shaft usable.

The vertical arrangement suits completed buildings, where the net is protection for maintenance staff rather than for a working shaft. It is also the arrangement that survives a lift installation without being dismantled.

3. Void Fall Protection in Stair Wells

A stair well is a series of voids that move as the stair rises, and the protection has to follow the geometry rather than sit on a grid. That is what makes void fall protection in a stair core more fiddly than the same area on a flat slab.

The usual approach is a horizontal net at each landing level, cut around the stair flight and laced to the surrounding structure. The cut is the expensive part, because every edge needs a terminal and every panel is a different shape.

A vertical net on the open side of the flight is the alternative. It is cheaper and faster, and it protects the person on the stair rather than the space beside it, which is often the actual hazard.

Longen flags any stair panel that lands within a protected enclosure for a fire review before fabrication, which is cheaper than discovering it at handover. Where the stair is a fire escape, the net must not obstruct the protected route. Check the fire strategy before fixing anything to the enclosure walls, because the fixings may penetrate a fire-rated lining.

Where the stair core is open to an atrium, the two problems merge. A single atrium safety net across the top of the core then serves both, and the void fall protection question becomes a question about the net above rather than the net beside.

4. Atrium Safety Net Aperture and Light

The aperture decision in an atrium is a daylight calculation and a retention decision at once. A fine panel solves retention and costs light; a coarse panel does the reverse, and there is no setting that satisfies both without a compromise.

A practical approach is to model the shadow before ordering. A panel at 60 mm aperture and 3 mm rope blocks a smaller proportion of light than one at 50 mm and 4 mm, and the difference is visible on a bright day.

Colour matters as much as size in a bright space. A bright mill finish reflects light and disappears against a glazed roof, while a black oxide finish reads as a deliberate line and suits a darker interior.

ApertureRopeLight transmissionTypical atrium use
40 mm3.0 mmModerateRetail, where dropped items matter
60 mm3.0 mmGoodHotel and office atrium
80 mm4.0 mmGoodLarge civic space, debris duty
100 mm5.0 mmHighSculptural screens, minimal shadow

The table assumes a mid-grey rope in a clean condition. Dust on the ropes reduces transmission over time, which is one more argument for a finish that can be washed without discolouring.

5. Void Fall Protection Anchoring Into Concrete

Anchoring is where an interior installation is decided. Concrete slabs accept cast-in anchors during construction and through-bolts afterwards, and the choice changes both the cost and the programme.

Cast-in anchors are cheaper and stronger, and they require the net layout to be fixed before the slab is poured. On a project where the net is an afterthought, that window has already closed.

Through-bolts work afterwards and need access to the underside of the slab, which in an atrium is often the finished ceiling of the floor below. Drilling into a finished ceiling is the detail that turns a small job into a large one.

Where neither is possible, the net can be carried on a perimeter cable fixed to the structural frame through the ceiling void. That detail keeps the fixings out of sight and concentrates the load into a few points that the frame can carry.

6. Access, Rescue and Maintenance

A net in an occupied building has to be maintainable without closing the space. That means access panels, cleaning routes and a documented way to reach every panel.

Rescue is the part that gets forgotten. A person who has fallen into a net is uninjured and stranded, and the plan for getting them out has to exist before the net is commissioned. In an atrium that usually means a mobile tower and a trained team.

Cleaning is a schedule rather than an event. Interior nets collect dust on the upper face of every rope, and a panel that is not washed looks tired within three or four years.

Hebei Longen Wire Mesh Products Co Ltd supplies a maintenance sheet with each interior order that lists the panels, the access points and the tension figures, so that a facilities team inherits a document rather than a memory. Longen Wire Mesh Products also marks the access panels on the drawing, which saves a contractor an hour with a ladder and a tape.

7. Lift Shaft Protection Net and Fire Strategy

A lift shaft is a vertical route for smoke, and anything fixed inside it affects that route. A lift shaft protection net with a fine aperture can slow smoke movement, which is sometimes useful and sometimes a breach of the smoke clearance design.

The fire consultant should see the net layout before fabrication. A coarser panel may be required in the shaft, and the panel may need to be non-combustible, which points to stainless rope in every case.

Fire-rated fixings are the second question. A net fixed with polymer anchors into a shaft wall may compromise the rating of the wall, and the anchor type has to be agreed with the same consultant.

None of this is difficult when it is asked early. It becomes expensive when a shaft is complete, the lift is installed and a net has to be retrofitted around a working car.

8. Void Fall Protection Handover Checks

Handover for an interior net has four parts: tension, anchors, access and records. Each takes minutes and each prevents a future argument.

Tension is measured as sag at mid span and compared with the installation drawing. Anchors are checked for torque and for the presence of the specified fixing rather than a substitute.

Access is walked rather than read. A panel that cannot be reached with the building's own equipment is a panel that will be cut open the first time someone needs to get past it.

Records complete the set. A handover file with the panel schedule, the anchor layout, the tension values and the inspection dates is what a facilities manager needs, and it costs the supplier an afternoon.

9. Frequently Asked Questions

9.1 Can an atrium net be installed in an occupied building?

Yes, and most interior work happens that way. The sequence is planned around public hours, with panels lifted out of hours and tensioning done during the day from a protected platform. Dust and noise are the two constraints, so drilling is batched into night shifts and the finished ceiling is protected before any work starts. Expect a longer programme than an empty building and a smaller crew rather than a different method, and where the space is open to the public a crash deck under the installation zone is worth the cost, because a dropped tool from six metres reaches a shopper in under two seconds.

9.2 How wide can a lift shaft panel be?

A lift shaft protection net panel is limited by the shaft dimensions and by what a person can handle inside the shaft, which is usually about 2 m by 2 m. Wider panels are possible and they become difficult to lift through a landing door. On a shaft of 2.5 m by 2.5 m, a single panel per level is normal, with a 150 mm clearance to the wall for installation tolerance. Anything larger than that needs a lifting plan and a platform rated for the panel weight, which changes the sequence rather than the material.

9.3 Does a stair net need to be fire rated?

The net itself is stainless steel and does not burn, so the material is not the issue. The question is the effect on the protected route and on the smoke strategy. A net across a stair void can change air movement, and the fixings can penetrate a rated lining, so send the layout to the fire consultant and keep the response with the handover file. On a pressurised stair, the extra resistance of a fine panel can change the fan duty, and that calculation should be done by the engineer who sized the fans.

9.4 What happens if someone falls into the net?

The net arrests them and the person is then stranded, which is why a rescue plan is part of the design. The panel is inspected before it is returned to service, since a loaded net will have moved at the crossings and may need re-tensioning. Record the event, photograph the impact area and check the anchors, because the next inspection is measured against that record. A net that has caught a person is also a net with a story, and the next occupant of the building will ask about it, so keep the file complete.